GX 6000 PID Gas Monitor

SDME2_Medium-1

Contact Our
Sales

The SDM-E2 is a versatile maintenance tool for the Eagle 2 portable gas monitor. This docking station can be used as a stand-alone device for charging, calibration and bump testing, with all records automatically stored for future upload to a PC via USB flash drive (PC software and flash drive included).

Multi Module System
The SDM-E2 can also be connected to a PC for automated calibration bump testing and archiving of datalog data from Eagle 2 instruments. Up to ten SDM-E2 docking stations can be connected simultaneously using USB cables. The SDM-E2 is also equipped with two gas ports to connect up to two calibration gas mixtures to the multi module system.



  • Stand Alone Station

    • Stand-alone station (no connection to PC Required)
    • Charging (NiMH batteries)
    • Calibration
    • Bump Test
    • Save bump test and calibration records
    • Bump test and calibration records copy to USB jump drive
    • 2 Calibration gas ports
    • Includes PC software for viewing/archiving bump test and calibration records

    Multi Module System

    • Multiple modules connected to a PC (10 max)
    • Charging
    • Calibration
    • Bump Test
    • Configure Eagle 2 parameters
    • 2 Calibration gas ports
    • Archive Bump Test and Calibration records
    • Archive data to network location
    • Software controlled data retrieval
    • Automatic calibration/bump test option
    • Windows 7 compatible
  • Multi Module System

    • Multiple modules connected to a PC (10 max)
    • Charging
    • Calibration
    • Bump Test
    • Configure Eagle 2 parameters
    • 2 Calibration gas ports
    • Archive Bump Test and Calibration records
    • Archive data to network location
    • Software controlled data retrieval
    • Automatic calibration/bump test option
    • Windows 7 compatible

Input Power

AC Adapter with 100 – 240 VAC, 50/60 Hz, 0.6A input and 112 VDC, 1.2A output provided as standard.

Environmental Conditions

• For Indoor Use Only

• -10° C to 40° C, below 80% relative humidity, non condensing

Applicable Instrument

Eagle 2

Maximum Number of Records Saved

200

Calibration Gas Ports

Connect up to 2 calibration gas cylinders to each station

Standard Accessories

• AC adapter

• USB flash drive

• Single module data viewer software

• SDM Docking station PC
controller software

• Inlet air filter

• Instrument manual

• 10’ exhaust tube



Specifications subject to change without notice.

Docking Station*

81-SDME2-01

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing & installation CD

81-SDME2-02

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing, installation CD, & demand flow regulator

81-SDME2-03

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, fla sh drive, USB cable, tubing, installationtion CD, demand flow regulator, & 58AL cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2

81-SDME2-08-P1

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator, 58AL cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2, & 103L cyl 10 ppm isobutylene in Air

81-SDME2-08-P2

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator, 58AL cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2, & 103L cyl 100 ppm isobutylene in Air

*Bold features indicate differences between the various versions of the docking stations.

Calibration Gases & Regulators

33-6010RK-04

CO2 scrubber (required for 0-10,000 ppm or 0-5% CO2 sensors)

81-0002RK-03

Cylinder, H2, 50% LEL in Air, 103L

81-0013RK-05

Cylinder, Methane, 50% volume in N2, 58L steel

81-0071RK-03

Cylinder, CO2, 5000 ppm in N2, 103L

81-0072RK-03

Cylinder, CO2, 2.5% in N2, 103L

81-0073RK-03

Cylinder, CO2, 15% in N2, 103L

81-0078RK-03

Cylinder, N2 100%, 103L

81-0089RK-03

Cylinder, CO 50 ppm / Hexane 15% LEL / O2 12 % in N2, 103L

81-0090RK-03

Cylinder, CO 50 ppm / Methane 50% LEL / O2 12 % in N2, 103L

81-0103RK-03

Cylinder, Isobutylene 100 ppm in Air, 103L

81-0104RK-03

Cylinder, Isobutylene 10 ppm in Air, 103L

81-0142RK-02

Cylinder, SO2 5 PPM / H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 58AL

81-0142RK-04

Cylinder, SO2 5 PPM / H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 34AL

81-0151RK-02

Cylinder, H2S 25 ppm in N2, 58AL

81-0154RK-02

Cylinder, H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 58AL

81-0155RK-02

Cylinder, H2S 25 ppm / CO 50 ppm / HEX 15% LEL / O2 12% in N2, 58AL

81-0170RK-04

Cylinder, SO2 5 ppm in N2, 34AL

81-1054RK

Regulator, demand flow for 34AL/58AL/103L



Specifications subject to change without notice