FP-300

Contact Our
Sales

  • Description
  • Features
  • Applications
  • Specifications
  • Download
  • Gases

RKI’s paper tape monitors utilize highly sensitive colorimetric tapes to achieve interference free detection at low PPB and PPM levels Ammonia, Arsine, Chlorine, Diborane, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Phosphine, Silane. The FP-300 is equipped with an easily replaceable tape. This model is equipped with a digital display showing the type of gas and concentration in PPM or PPB. The FP-300 will also display remaining tape life as well as an end of tape alarm.

The FP-300 has audible and visual alarms, as well as alarm relay contacts and 4-20mA output. A unique “tape saver mode” extends tape life in applications where high background gas levels may be present.

The FP-300 meets and exceeds OSHA and NIOSH compliance requirements, and does not respond to interfering gases (hydrocarbons, alcohols, solvents, CO, etc.) that may be present in industrial/manufacturing environments. FP 330

  • Small and compact
  • Highly sensitive and ideal for low gas concentrations (ppb detection)
  • Interference-free detection
  • Easy detection tape replacement with plug-in cassette
  • Tape remainder display and tape end warning alarm provided
  • Easily transportable
  • Scrubbers
  • Environmental Monitoring
  • Semiconductor Fabs
  • Manufacturing
  • Detecting uncaptured gas from scrubber
ModelFP-300
Detection principlePhotoelectric photometry method using tape cassette
Detection tapePlug in cassette
Detection rangesee the table above
AccuracyWithin +/- 20% +1 of indication
Tape operation time1 month (with now alarm)
Tape remainder display,
Tape end warning
Alarm preset pointSee the table above
Alarm functionsLatching (standard) or self reset. Lamp (Caution: Yellow, Warning: Red) and buzzer
Self-diagnosisSensor failure, low flow, tape failure, tape end warning, failure of tape setting, system error
External output signal4-20mA (300 Ω at maximum load resistance)
Operating temperature & humidity41-95°F (5~35°C)
30~90% RH (non condensing)
Power supply & power24VDC +/- 10% for panel mounting 100 VAC, 110 VAC, 117 VAC, 220 VAC for desktop
Dimensions & weightPanel mounting: Approx. 6.5(W) x 6.5(H) x 10.3(D) Approx. 14.33lb

Desktop: Approx. 6.5(W) x 7.8(H) x 10.4(D) Approx. 12.125lb

 

GasTLVDetection RangeResolution1st alarm2nd alarmTape No.
Amonia
NH3
25ppm0.5~4ppm0.1ppm1ppm2ppmFC-010
Arsine
AsH3
50ppb0~150ppb1ppb50ppb100ppbFCL-001
Chlorine
Cl2
0.5ppm*0~0.8ppm0.01ppm0.25ppm0.5ppmFCL105
0~1.5ppm
Diborane
B2H6
100ppb0~300ppb5ppb50ppb100ppbFCL-002
Hydrogen Chloride
HCl
5ppm0.25~1ppm0.025ppm0.5ppm0.75ppmFC-004
1.5~8ppm0.1ppm2.5ppm5ppmFC-005
Hydrogen Fluoride
HF
3ppm0~9ppm0.1ppm1.5ppm3ppmFC-006
Hydrogen Sulfide
H2S
10ppm0~100ppm1ppb17ppb34ppbFCL-001
0~10ppm0.05ppm1ppm2ppm
Phosphine
PH3
300ppb*0~500ppb5ppb150ppb300ppbFCL-001
0~900ppb
Silane
SiH4
5ppm*0~8ppm0.1ppm2.5ppm5ppmFCL-002
0~15ppm