FP-300

Contact Our
Sales

    Contact Our Sales





    • Description
    • Features
    • Applications
    • Specifications
    • Download
    • Gases

    RKI’s paper tape monitors utilize highly sensitive colorimetric tapes to achieve interference free detection at low PPB and PPM levels Ammonia, Arsine, Chlorine, Diborane, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Phosphine, Silane. The FP-300 is equipped with an easily replaceable tape. This model is equipped with a digital display showing the type of gas and concentration in PPM or PPB. The FP-300 will also display remaining tape life as well as an end of tape alarm.

    The FP-300 has audible and visual alarms, as well as alarm relay contacts and 4-20mA output. A unique “tape saver mode” extends tape life in applications where high background gas levels may be present.

    The FP-300 meets and exceeds OSHA and NIOSH compliance requirements, and does not respond to interfering gases (hydrocarbons, alcohols, solvents, CO, etc.) that may be present in industrial/manufacturing environments. FP 330

    • Small and compact
    • Highly sensitive and ideal for low gas concentrations (ppb detection)
    • Interference-free detection
    • Easy detection tape replacement with plug-in cassette
    • Tape remainder display and tape end warning alarm provided
    • Easily transportable
    • Scrubbers
    • Environmental Monitoring
    • Semiconductor Fabs
    • Manufacturing
    • Detecting uncaptured gas from scrubber
    ModelFP-300
    Detection principlePhotoelectric photometry method using tape cassette
    Detection tapePlug in cassette
    Detection rangesee the table above
    AccuracyWithin +/- 20% +1 of indication
    Tape operation time1 month (with now alarm)
    Tape remainder display,
    Tape end warning
    Alarm preset pointSee the table above
    Alarm functionsLatching (standard) or self reset. Lamp (Caution: Yellow, Warning: Red) and buzzer
    Self-diagnosisSensor failure, low flow, tape failure, tape end warning, failure of tape setting, system error
    External output signal4-20mA (300 Ω at maximum load resistance)
    Operating temperature & humidity41-95°F (5~35°C)
    30~90% RH (non condensing)
    Power supply & power24VDC +/- 10% for panel mounting 100 VAC, 110 VAC, 117 VAC, 220 VAC for desktop
    Dimensions & weightPanel mounting: Approx. 6.5(W) x 6.5(H) x 10.3(D) Approx. 14.33lb

    Desktop: Approx. 6.5(W) x 7.8(H) x 10.4(D) Approx. 12.125lb

    GasTLVDetection RangeResolution1st alarm2nd alarmTape No.
    Amonia
    NH3
    25ppm0.5~4ppm0.1ppm1ppm2ppmFC-010
    Arsine
    AsH3
    50ppb0~150ppb1ppb50ppb100ppbFCL-001
    Chlorine
    Cl2
    0.5ppm*0~0.8ppm0.01ppm0.25ppm0.5ppmFCL105
    0~1.5ppm
    Diborane
    B2H6
    100ppb0~300ppb5ppb50ppb100ppbFCL-002
    Hydrogen Chloride
    HCl
    5ppm0.25~1ppm0.025ppm0.5ppm0.75ppmFC-004
    1.5~8ppm0.1ppm2.5ppm5ppmFC-005
    Hydrogen Fluoride
    HF
    3ppm0~9ppm0.1ppm1.5ppm3ppmFC-006
    Hydrogen Sulfide
    H2S
    10ppm0~100ppm1ppb17ppb34ppbFCL-001
    0~10ppm0.05ppm1ppm2ppm
    Phosphine
    PH3
    300ppb*0~500ppb5ppb150ppb300ppbFCL-001
    0~900ppb
    Silane
    SiH4
    5ppm*0~8ppm0.1ppm2.5ppm5ppmFCL-002
    0~15ppm