The Gas Tracer is excellent for testing and detection of small gas leaks.

Built around high-quality micro-sensor technology, the GX-2012 is RKI’s smallest personal 1-5 sensor gas monitor with a built in sample pump. Weighing only 12.3 ounces, the GX-2012 can monitor the standard confined space gases (LEL combustibles, Oxygen content, Carbon Monoxide, and Hydrogen Sulfide).

The GX-2012’s large LCD display shows all gas readings, battery level, current time, and will automatically backlight in alarm conditions. Standard alarm types include vibration, visual, and audible alarms, which can be set to latching or non-latching. Controlled by a microprocessor, the GX-2012 continuously checks itself for sensor connections, low battery, circuit trouble, low flow, and calibration errors. The GX-2012 can interchangeably operate on either a Li-ion battery pack or an alkaline battery pack. The batteries are simple to replace requiring no tools to access the removable battery compartment or pack.

Gas Detected

Combustible Gases 
(Methane as standard)

% Volume 
Methane

Oxygen (O2)

Hydrogen Sulfide (H2S)

Carbon Monoxide (CO)

Detection Principle

Catalytic combustion

Thermal conductivity

Galvanic cell

Electrochemical cell

Detection Range

0 ~ 100% LEL
0 ~ 500 / 1,000 / 2,000 / 5,000 ppm

0 ~ 100% Vol.

0 ~ 40% Vol.

0 ~ 100 ppm
(optional 0-500 ppm)

0 ~ 500 ppm

Accuracy Statement 
(whichever is greater)

± 5% of reading or
± 2% LEL

(LEL mode only)

± 5% of reading or ± 2% of full scale

± 0.5% O2

± 5% of reading or ± 2ppm H2S

± 5% of reading or ± 5 ppm CO

Sampling Method

Internal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter

Display

Digital LCD with 7 segments, auto backlight during alarm

Preset Alarms
(User Adjustable)

1st alarm 10% LEL
2nd alarm 50% LEL
Over alarm 100% LEL

No alarms for
% Vol. CH4

Low alarm 19.5% High alarm 23.5% Over alarm 40.0%

1st 5 ppm
2nd 30 ppm
TWA 10 ppm
STEL 15 ppm
Over 100 ppm

1st 25 ppm
2nd 50 ppm
TWA 25 ppm
STEL 200 ppm
Over 500 ppm

Alarms Types

Gas alarms: 1st and 2nd, STEL, TWA (user adjustable) and OVER
Trouble alarms: Sensor connection, low battery, low flow, circuit trouble and calibration error

Alarm Methods

Gas alarms: Flashing lights, two tone buzzer, and vibration
Trouble alarms: Flashing lights, trouble displayed, intermittent buzzer, and vibration

Operating Temp. & Humidity

-20°C to +50°C (-4°F to 122°F)
0 to 95% RH, non-condensing

Response Time

Within 30 seconds (T90)

Continuous Operation

Alkaline battery: 15 hours Li-Ion battery: 10 hours
70°F (21°C)

Power Source

Li-Ion battery pack, or 3 “AA” Alkaline battery pack; interchangeable

Safety Rating

ATEX, TIIS, IECEx, CE, CSA classified (as standard), as intrinsically safe. Class I, Division 1, Groups A, B, C, D (optional version available)

Dimension & Weight

Approx. 143 (H) x 71 (W) x 43 (D) mm (5.6” H x 2.8” W x 1.6” D), approx. 350 g (12.3 ounces)

Case Material

High dust & water resistant design. RFI shielded high impact plastic with protective rubber overmolding

Controls

Five buttons: POWER / ENTER, DISPLAY, AIR, RESET, SHIFT

Standard Accessories

  • •Belt clip
  • Rubber nozzle, 3.5”
  • Datalogging software
  • 10” Probe
  • Manual
  • Quick reference card
  • 10’ Hose
  • Training CD

Optional Accessories

  • SDM-2012 calibration stations
  • Calibration kit
  • Li-Ion battery pack
  • AC or DC Charger
  • Sample draw hoses (10’ standard, up to 100’ max. available)
  • Carrying case

Configurations

1, 2, 3, 4, or 5 sensor units
Li-Ion or alkaline battery pack options

Warranty

Two years material and workmanship

    • Monitors ppm, LEL, and % volume methane, O2 and CO
    • PPM leak detector, detects down to 10 ppm CH4
    • “Leak tracker” audible/visual alarm mode for CH4 and CO
    • 0 to 100% volume Methane option
    • Auto-ranging display of % LEL and % volume
    • Barhole test mode
    • Bump test reminder option
    • Snap-logging – on demand data recording
    • Pump pause on demand
    • Internal sample drawing pump with up to 50 foot range
    • Lithium ion or alkaline power battery packs (interchangeable)
    • Up to 600 hours of datalogging with alarm trends
    • Intrinsically safe, ATEX/IECEx/CE or c CSA us (Optional)
  • Built around high-quality micro-sensor technology, the Gas Tracer is RKI’s smallest personal 5 sensor monitor with a built in sample pump.
Gas Detected
Combustible Gases
(Methane as standard)
% Volume
Methane
PPM
Methane
Oxygen (O2)
Carbon Monoxide (CO)
Detection Principle
Catalytic combustion
Thermal conductivity
MOS
catalytic
Galvanic cell
Electro- chemical cell
Detection Range
0 ~ 100% LEL
0 ~ 100% Vol.
0 ~ 5000 ppm
optional 10,000 ppm range version available
0 ~ 40% Vol.
0 ~ 500 ppm
Accuracy Statement
(whichever is greater)
± 5% of reading or
± 2% LEL
± 5% of reading or ± 2% of full scale
± 10% of reading or ± 50 ppm CH4
± 0.5% O2
± 5% of reading or ± 5 ppm CO
Sampling MethodInternal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter
DisplayDigital LCD with 7 segments, auto backlight during alarm
Preset Alarms
(User Adjustable)
1st alarm 10% LEL
2nd alarm 50% LEL
Over alarm 100% LEL
No alarms for
% Vol. CH4
Increasing tone/light pulse as concentration increasesLow alarm 19.5% High alarm 23.5% Over alarm 40.0%1st 25 ppm
2nd 50 ppm
TWA 25 ppm
STEL 200 ppm
Over 500 ppm
Alarms TypesLeak Tracker Mode: Escalating audible/visual alarm, changes with gas level (audible can be turned off)
Gas alarms: 1st and 2nd, STEL, TWA (user adjustable) and OVER
Trouble alarms: Sensor connection, low battery, low flow, circuit trouble and calibration error
Alarm MethodsGas alarms: Flashing lights, two tone buzzer, and vibration
Trouble alarms: Flashing lights, trouble displayed, intermittent buzzer, and vibration
Operating Temp. & Humidity-20°C to +50°C (-4°F to +122°F)
0 to 95% RH, non-condensing
Response TimeWithin 30 seconds (T90)
Continuous OperationAlkaline battery: 15 hours Li-Ion battery: 10 hours
70°F (21°C)
Power SourceLi-Ion battery pack, or 3 “AA” Alkaline battery pack; interchangeable
Safety RatingATEX, TIIS, IECEx, CE, or optionally: c CSA us classified, as intrinsically safe. Class I, Division 1, Groups A, B, C, D
Note: Either ATEX (USA and worldwide) or CSA (Canada) version must be specified when ordering.
Dimension & WeightApprox. 143 (H) x 71 (W) x 43 (D) mm (5.6” H x 2.8” W x 1.6” D), approx. 350 g (12.3 ounces)
Case MaterialHigh dust & water resistant design. RFI shielded high impact plastic with protective rubber overmolding
ControlsFive buttons: POWER / ENTER, DISPLAY, AIR, RESET, SHIFT
Standard Accessories• Belt clip • Rubber nozzle, 2.5” • Datalogging software
• 10” Probe • Manual • Quick reference card
• 10’ Hose • Training CD
Optional Accessories• SDM-2012 calibration stations • Calibration kit
• Li-Ion battery pack • AC or DC Charger
• Sample draw hoses (10’ standard, up to 50’ max. available) • Carrying case
Configurations1, 2, 3, 4, or 5 sensor units
Li-Ion or alkaline battery pack options
WarrantyTwo years material and workmanship

Parts

#Part NumberDescription
1.17-1001RKTapered rubber inlet nozzle, 4”, RP-6, GX-2003, or Gas Tracer
2.21-1833RKFilter holder, clear plastic, GX-2003
3.33-1031RKCotton balls, filters for probe, bag of 25
4.33-0159RKTeflon filter disc, 10 pieces, RP-6 / GX-2003
5.33-1112RKWire mesh disk filter, RP-6 / GX-2003 / Gas Tracer, 10 pack
6.21-1890RKTop cover assembly, Gas Tracer
7.30-0022RKPump replacement for Gas Tracer and RP-2009, with cable and connector
8.21-1891RKMain case assembly, Gas Tracer
9.07-6024RKBattery pack gasket, Gas Tracer / Gas Tracer
10.07-6025RKMain case gasket, Gas Tracer / Gas Tracer
11.51-1125RKLCD display, Gas Tracer / Gas Tracer
12.57-2044RKCPU PC board assembly, Gas Tracer
13.49-1406RKBattery, lithium, CR 1220, for main PCB, Gas Tracer / Gas Tracer
14.30-1053RKVibration motor, GX-2003
15.10-1090RKTap tight screw M2x4.5 mm, phillips self-tapping
16.57-2042RKSensor PC board assembly, Gas Tracer
17.07-6026RKSensor gasket, Gas Tracer / Gas Tracer
18.33-7114RKFilter disk, H2S scrubber, 5 pack, for combustible diffusion port, set of 2, GX-2009 / GX-2001
19.33-7102RKFilter, charcoal, for CO sensor, pack of 5
20.21-1892RKSensor cap assembly, Gas Tracer
21.13-0118RKBelt clip, Gas Tracer / Gas Tracer
22.49-1615RKBatter pack, lithium ion, Gas Tracer / Gas Tracer
23.49-1616RK-01Alkaline Battery pack cover with gasket, Gas Tracer / Gas Tracer
24.49-1616RK-02Alkaline Battery pack without cover with gasket, Gas Tracer / Gas Tracer
25.13-0112RKWrist strap, GX-2001/GX-2003/GX-2009
26.10-1108RKScrew M2 x 16 SUS304 (100 pcs)
27.10-1093RKScrew M2 x 6 SUS304 (100 pcs)
28.10-1091RKScrew M2 x 5 SUS (100 pcs)
29.10-1092RKTruss screw M2 x 5 SUS (100 pcs)
30.OS-BM2O2 sensor OS-BM2
31.NC-6264ALEL sensor NC-6264AS
32.ES-1821CO sensor ES-1821
33.ES-1827IH2S sensor ES-1827I
34.TE-7561VOL sensor TE-7561
35.SH-8641PPM sensor SH-8641
36.49-1616RKAlkaline Battery pack without batteries with gasket, Gas Tracer / Gas Tracer

 