GX 6000 PID Gas Monitor

  • 6 Operating modes
  • Smallest 6 gas sample draw
  • 2 Interchangeable smart sensor slots
  • 4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
  • PID library of over 600 VOCs
    — Easily switch target VOC from customizable user list or a recently used list
  • Benzene specific version
  • PPM Leak Check mode
  • LEL sensor protection mode
  • Man-down alarm
  • Panic alarm • Auto display rotation
  • Peak-bar display
  • LED Light source
  • Internal sample pump
  • Light weight, small, rugged IP-67 design
  • Interchangeable battery packs (Li-ion / alkaline)
  • Operates up to 14 hours on Li-ion battery pack, fully recharges in 3 hours; 8 hours operation with alkaline pack
  • Field replaceable sensors, batteries, filters and pump
  • Intrinsically safe ATEX / IECEx / cCSAus

    Contact Our Sales





    • Description
    • Features
    • Applications
    • Specifications
    • Parts
    • Download
    • Training Video

    Simply put, the GX-6000 is a game changer. This powerful hand-held PID gas monitor is capable of simultaneously monitoring up to 6 gases.

    6 Gas Monitor,

    • PID gas monitor with simultaneous detection and display.
    • Dual VOC display with 2 PID sensors installed.
    • Monitor the standard 4 confined space gases which include combustibles, O2, CO, & H2S
    • GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors.

    Safety Features

    The GX-6000 is equipped with a strong internal sample pump in addition to advanced safety features.

    • Man-down alarm
    • Panic alarm
    • LED flashlight
    • Large auto rotating LCD display

    PID Gas Monitor

    The GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed.

    • 30 of the commonly used VOC’s.
    • 8 of the most recently used VOC’s.

    Reliable and Durable

    The GX-6000 is a rugged personal PID gas monitor built for the nastiest environments. Most noteworthy, it is equipped with a removable impact-resistant rubber boot.

    • Dust and water resistant enclosure with an IP-67 rating.
    • 5 bright LED lights on 3 sides of the instrument.
    • View Alarms easily from a variety of perspectives.
    • Vibration and loud audible alarm for immediate notification.

    Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene.

    Applications

    • Confined space entry
    • Hazmat response teams
    • Arson investigation
    • Remediation sites
    • Perimeter monitoring
    • Leak detection
    • Landfill monitoring
    • Wing tank entry

    Gases & Detectable Ranges

    GasMeasuring Range

    Reading

    Increment

    Alarm

    Set Points

    Accuracy

    (which ever
    is greater)

    PID Sensors
    10.6 Lamp600 VOC’s0 – 50,000 ppb

    1 ppb: (< 5000 ppb)

    10 ppb: (> 5,000 ppb)

    A1: 5,000 ppb

    ± 10% of reading,

    ± 1 digit

    A2: 10,000 ppb
    0 – 6,000 ppm0.1 ppm: (< 600 ppm)
    1 ppm: (> 600 ppm)
    A1: 400 ppm
    A2: 1,000 ppm
    10.0 LampBenzene Specific0.1 – 50 ppm0.01 ppm (0 ~ 10 ppm)
    0.1 ppm (10 ~ 50 ppm)
    No Alarms
    300 VOC’s0 – 100 ppm0.01 ppm (0 ~ 10 ppm)
    0.1 ppm (10 ~ 100 ppm)

    A1: 5 ppm

    A2: 10 ppm

    11.7 LampHigh Voltage Lamp0 – 1000 ppm0.1 ppmA1: 400 ppm
    A2: 1,000 ppm
    Galvanic
    Oxygen (O2)0 – 40.0% Vol.0.1% Vol.A1: 19.5 Vol.± 0.5% O2
    A2: 23.5 Vol.
    Electro Chemical
    Carbon Monoxide (CO)0 – 500 ppm1 ppmA1: 25 ppm± 5% of
    reading or
    ± 5 ppm
    A2: 50 ppm
    TWA 25 ppm
    STEL 200 ppm
    Hydrogen Sulfide (H2S)0 – 100.0 ppm0.5 ppmA1: 5.0 ppm± 5% of
    reading or
    ± 2 ppm
    A2: 30.0 ppm
    TWA 1.0 ppm
    STEL 5.0 ppm
    Toxics (EC Sensors)
    Ammonia (NH3)0 – 400.0 ppm0.5 ppmA1: 25 ppm± 10% of
    reading or ± 5% of full scale
    A2: 50 ppm
    Chlorine
    (Cl2)
    0 – 10.00 ppm0.05 ppmA1: 0.5 ppm
    A2: 1.0 ppm
    Hydrogen Cyanide (HCN)0 – 15.0 ppm0.1 ppmA1: 5 ppm
    A2: 10 ppm
    Nitrogen Dioxide (NO2)0 – 20.00 ppm0.05 ppmA1: 3 ppm
    A2: 6 ppm
    Sulfur Dioxide (SO2)0 – 99.90 ppmA1: 2 ppm
    A2: 5 ppm
    IR Sensors
    Carbon Dioxide (CO2)0 – 10,000 ppm20 ppmA1: 5,000 ppm± 5% of
    reading or ± 2% of full scale
    TWA 5,000 ppm
    0 – 10.00% Vol.0.02%A1: 0.50% Vol
    A2: 3.00% Vol
    STEL 3.00% Vol
    TWA 0.50% Vol
    Methane (CH4)

    0 – 100% LEL

    0 – 100% Vol.

    1% LEL/
    0.5% Vol

    A1: 10% LEL

    A2: 50% LEL

    Hydrocarbons0 – 100% LEL
    0 – 30% Vol.
    Catalytic
    Hydrocarbons (CH4, std)0 – 100% LEL1% LELA1: 10%LEL± 5% of
    reading or ± 2% LEL
    A2: 50%LEL

    Common Specifications

    Alarm TypesGas alarmMan-downTrouble
    Low and high adjustable

    1st – self reset

    2nd – latching

    Low flow

    Sensor connection

    Low battery

    Circuit error

    Calibration range

    Sample MethodSample draw pump, flow rate 0.45 LPM, 50 foot sample range
    DisplayDigital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases
    Audible Alarm95 dB at 1 ft.
    LanguagesEnglish, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian
    Continuous
    Operation

    14 hours on Lithium-ion battery pack. Complete recharge in 3 hours.

    8 hours Alkaline battery pack (3 AA size within each pack)

    Operating Temp.
    & Humidity
    -4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing
    Dimensions2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm)
    14 ounce (400g) (with lithium battery pack)
    Case MaterialDust and water resistant with IP-67 approval
    (exclude sample hose and probe)

    Safety Design /

    Approvals

    Explosion proof: IECEx , ATEX , TIIS , cCSAus

    Explosion class :Ex ia IIC T4 Ga Others: CE Marking

    Standard
    Features

    2 Smart sensors slots auto recognize sensor changes

    Library of over 600 VOC’s

    User defined VOC list. Up to 30 frequently used

    Recent VOC list for last 8 selected gases

    Pump and circuit status indicators

    User & station ID selection menu

    Datalogging (interval, alarm trend, station and user ID)

    Snap logging – on demand data logging

    Demand zero / Auto zero

    BUMP and CAL expiration alarm

    Flashlight

    IrDA communication

    LEL sensor protection mode

    Standard
    Accessories
    • Rubber boot • Belt clip
    • Hand strap • Tapper nozzle• Probe with hydrophobic & dust filter 3’ teflon lined hose• Benzene pre-filter tubes and holder (benzene versions)
    Optional
    Accessories

    • SDM-6000 calibration station

    • Bundles with instrument carrying case and accessories

    • Flexible probes

    • Up to 50 foot sample hoses

    • Filter set

    • IrDA cable

    WarrantyTwo years material (including sensors) and
    workmanship. One year for PID sensor (Two monthsfor 11.7 eV lamp)
    • 6 Operating modes
    • Smallest 6 gas sample draw
    • 2 Interchangeable smart sensor slots
    • 4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
    • PID library of over 600 VOCs
      — Easily switch target VOC from customizable user list or a recently used list
    • Benzene specific version
    • PPM Leak Check mode
    • LEL sensor protection mode
    • Man-down alarm
    • Panic alarm • Auto display rotation
    • Peak-bar display
    • LED Light source
    • Internal sample pump
    • Light weight, small, rugged IP-67 design
    • Interchangeable battery packs (Li-ion / alkaline)
    • Operates up to 14 hours on Li-ion battery pack, fully recharges in 3 hours; 8 hours operation with alkaline pack
    • Field replaceable sensors, batteries, filters and pump
    • Intrinsically safe ATEX / IECEx / cCSAus
    • Confined Space Entry
    • Hazmat Response Teams
    • Arson Investigation
    • Remediation Site
    • Perimeter Monitoring
    • Leak Detection
    • Landfill Monitoring
    • Winery Tank Entry

    Gases & Detectable Ranges

    GasMeasuring Range

    Reading

    Increment

    Alarm

    Set Points

    Accuracy

    (which ever
    is greater)

    PID Sensors
    10.6 Lamp600 VOC’s0 – 50,000 ppb

    1 ppb: (< 5000 ppb)

    10 ppb: (> 5,000 ppb)

    A1: 5,000 ppb

    ± 10% of reading,

    ± 1 digit

    A2: 10,000 ppb
    0 – 6,000 ppm0.1 ppm: (< 600 ppm)
    1 ppm: (> 600 ppm)
    A1: 400 ppm
    A2: 1,000 ppm
    10.0 LampBenzene Specific0.1 – 50 ppm0.01 ppm (0 ~ 10 ppm)
    0.1 ppm (10 ~ 50 ppm)
    No Alarms
    300 VOC’s0 – 100 ppm0.01 ppm (0 ~ 10 ppm)
    0.1 ppm (10 ~ 100 ppm)

    A1: 5 ppm

    A2: 10 ppm

    11.7 LampHigh Voltage Lamp0 – 1000 ppm0.1 ppmA1: 400 ppm
    A2: 1,000 ppm
    Galvanic
    Oxygen (O2)0 – 40.0% Vol.0.1% Vol.A1: 19.5 Vol.± 0.5% O2
    A2: 23.5 Vol.
    Electro Chemical
    Carbon Monoxide (CO)0 – 500 ppm1 ppmA1: 25 ppm± 5% of
    reading or
    ± 5 ppm
    A2: 50 ppm
    TWA 25 ppm
    STEL 200 ppm
    Hydrogen Sulfide (H2S)0 – 100.0 ppm0.5 ppmA1: 5.0 ppm± 5% of
    reading or
    ± 2 ppm
    A2: 30.0 ppm
    TWA 1.0 ppm
    STEL 5.0 ppm
    Toxics (EC Sensors)
    Ammonia (NH3)0 – 400.0 ppm0.5 ppmA1: 25 ppm± 10% of
    reading or ± 5% of full scale
    A2: 50 ppm
    Chlorine
    (Cl2)
    0 – 10.00 ppm0.05 ppmA1: 0.5 ppm
    A2: 1.0 ppm
    Hydrogen Cyanide (HCN)0 – 15.0 ppm0.1 ppmA1: 5 ppm
    A2: 10 ppm
    Nitrogen Dioxide (NO2)0 – 20.00 ppm0.05 ppmA1: 3 ppm
    A2: 6 ppm
    Sulfur Dioxide (SO2)0 – 99.90 ppmA1: 2 ppm
    A2: 5 ppm
    IR Sensors
    Carbon Dioxide (CO2)0 – 10,000 ppm20 ppmA1: 5,000 ppm± 5% of
    reading or ± 2% of full scale
    TWA 5,000 ppm
    0 – 10.00% Vol.0.02%A1: 0.50% Vol
    A2: 3.00% Vol
    STEL 3.00% Vol
    TWA 0.50% Vol
    Methane (CH4)

    0 – 100% LEL

    0 – 100% Vol.

    1% LEL/
    0.5% Vol

    A1: 10% LEL

    A2: 50% LEL

    Hydrocarbons0 – 100% LEL
    0 – 30% Vol.
    Catalytic
    Hydrocarbons (CH4, std)0 – 100% LEL1% LELA1: 10%LEL± 5% of
    reading or ± 2% LEL
    A2: 50%LEL

    Common Specifications

    Alarm TypesGas alarmMan-downTrouble
    Low and high adjustable

    1st – self reset

    2nd – latching

    Low flow

    Sensor connection

    Low battery

    Circuit error

    Calibration range

    Sample MethodSample draw pump, flow rate 0.45 LPM, 50 foot sample range
    DisplayDigital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases
    Audible Alarm95 dB at 1 ft.
    LanguagesEnglish, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian
    Continuous
    Operation

    14 hours on Lithium-ion battery pack. Complete recharge in 3 hours.

    8 hours Alkaline battery pack (3 AA size within each pack)

    Operating Temp.
    & Humidity
    -4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing
    Dimensions2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm)
    14 ounce (400g) (with lithium battery pack)
    Case MaterialDust and water resistant with IP-67 approval
    (exclude sample hose and probe)

    Safety Design /

    Approvals

    Explosion proof: IECEx , ATEX , TIIS , cCSAus

    Explosion class :Ex ia IIC T4 Ga Others: CE Marking

    Standard
    Features

    2 Smart sensors slots auto recognize sensor changes

    Library of over 600 VOC’s

    User defined VOC list. Up to 30 frequently used

    Recent VOC list for last 8 selected gases

    Pump and circuit status indicators

    User & station ID selection menu

    Datalogging (interval, alarm trend, station and user ID)

    Snap logging – on demand data logging

    Demand zero / Auto zero

    BUMP and CAL expiration alarm

    Flashlight

    IrDA communication

    LEL sensor protection mode

    Standard
    Accessories

    • Rubber boot • Belt clip
    • Hand strap • Tapper nozzle

    • Probe with hydrophobic & dust filter 3’ teflon lined hose

    • Benzene pre-filter tubes and holder (benzene versions)

    Optional
    Accessories

    • SDM-6000 calibration station

    • Bundles with instrument carrying case and accessories

    • Flexible probes

    • Up to 50 foot sample hoses

    • Filter set

    • IrDA cable

    Warranty

    Two years material (including sensors) and
    workmanship. One year for PID sensor (Two months

    for 11.7 eV lamp)

    GX 6000

    download datasheet