  • 6 Operating modes
  • Smallest 6 gas sample draw
  • 2 Interchangeable smart sensor slots
  • 4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
  • PID library of over 600 VOCs
    — Easily switch target VOC from customizable user list or a recently used list
  • Benzene specific version
  • PPM Leak Check mode
  • LEL sensor protection mode
  • Man-down alarm
  • Panic alarm • Auto display rotation
  • Peak-bar display
  • LED Light source
  • Internal sample pump
  • Light weight, small, rugged IP-67 design
  • Interchangeable battery packs (Li-ion / alkaline)
  • Operates up to 14 hours on Li-ion battery pack, fully recharges in 3 hours; 8 hours operation with alkaline pack
  • Field replaceable sensors, batteries, filters and pump
  • Intrinsically safe ATEX / IECEx / cCSAus
  • Description
  • Features
  • Applications
  • Specifications
  • Parts
  • Download
  • Training Video

Simply put, the GX-6000 is a game changer. This powerful hand-held PID gas monitor is capable of simultaneously monitoring up to 6 gases.

6 Gas Monitor,

  • PID gas monitor with simultaneous detection and display.
  • Dual VOC display with 2 PID sensors installed.
  • Monitor the standard 4 confined space gases which include combustibles, O2, CO, & H2S
  • GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors.

Safety Features

The GX-6000 is equipped with a strong internal sample pump in addition to advanced safety features.

  • Man-down alarm
  • Panic alarm
  • LED flashlight
  • Large auto rotating LCD display

PID Gas Monitor

The GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed.

  • 30 of the commonly used VOC’s.
  • 8 of the most recently used VOC’s.

Reliable and Durable

The GX-6000 is a rugged personal PID gas monitor built for the nastiest environments. Most noteworthy, it is equipped with a removable impact-resistant rubber boot.

  • Dust and water resistant enclosure with an IP-67 rating.
  • 5 bright LED lights on 3 sides of the instrument.
  • View Alarms easily from a variety of perspectives.
  • Vibration and loud audible alarm for immediate notification.

Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene.

Applications

  •  Confined space entry
  • Hazmat response teams
  • Arson investigation
  • Remediation sites
  • Perimeter monitoring
  • Leak detection
  • Landfill monitoring
  • Wing tank entry

Gases & Detectable Ranges

GasMeasuring Range

Reading

Increment

Alarm

Set Points

Accuracy

(which ever
is greater)

PID Sensors
10.6 Lamp600 VOC’s0 – 50,000 ppb

1 ppb: (< 5000 ppb)

10 ppb: (> 5,000 ppb)

A1: 5,000 ppb

± 10% of reading,

± 1 digit

A2: 10,000 ppb
0 – 6,000 ppm0.1 ppm: (< 600 ppm)
1 ppm: (> 600 ppm)
A1: 400 ppm
A2: 1,000 ppm
10.0 LampBenzene Specific0.1 – 50 ppm0.01 ppm (0 ~ 10 ppm)
0.1 ppm (10 ~ 50 ppm)
No Alarms
300 VOC’s0 – 100 ppm0.01 ppm (0 ~ 10 ppm)
0.1 ppm (10 ~ 100 ppm)

A1: 5 ppm

A2: 10 ppm

11.7 LampHigh Voltage Lamp0 – 1000 ppm0.1 ppmA1: 400 ppm
A2: 1,000 ppm
Galvanic
Oxygen (O2)0 – 40.0% Vol.0.1% Vol.A1: 19.5 Vol.± 0.5% O2
A2: 23.5 Vol.
Electro Chemical
Carbon Monoxide (CO)0 – 500 ppm1 ppmA1: 25 ppm± 5% of
reading or
± 5 ppm
A2: 50 ppm
TWA 25 ppm
STEL 200 ppm
Hydrogen Sulfide (H2S)0 – 100.0 ppm0.5 ppmA1: 5.0 ppm± 5% of
reading or
± 2 ppm
A2: 30.0 ppm
TWA 1.0 ppm
STEL 5.0 ppm
Toxics (EC Sensors)
Ammonia (NH3)0 – 400.0 ppm0.5 ppmA1: 25 ppm± 10% of
reading or ± 5% of full scale
A2: 50 ppm
Chlorine
(Cl2)
0 – 10.00 ppm0.05 ppmA1: 0.5 ppm
A2: 1.0 ppm
Hydrogen Cyanide (HCN)0 – 15.0 ppm0.1 ppmA1: 5 ppm
A2: 10 ppm
Nitrogen Dioxide (NO2)0 – 20.00 ppm0.05 ppmA1: 3 ppm
A2: 6 ppm
Sulfur Dioxide (SO2)0 – 99.90 ppmA1: 2 ppm
A2: 5 ppm
IR Sensors
Carbon Dioxide (CO2)0 – 10,000 ppm20 ppmA1: 5,000 ppm± 5% of
reading or ± 2% of full scale
TWA 5,000 ppm
0 – 10.00% Vol.0.02%A1: 0.50% Vol
A2: 3.00% Vol
STEL 3.00% Vol
TWA 0.50% Vol
Methane (CH4)

0 – 100% LEL

0 – 100% Vol.

1% LEL/
0.5% Vol

A1: 10% LEL

A2: 50% LEL

Hydrocarbons0 – 100% LEL
0 – 30% Vol.
Catalytic
Hydrocarbons (CH4, std)0 – 100% LEL1% LELA1: 10%LEL± 5% of
reading or ± 2% LEL
A2: 50%LEL

Common Specifications

Alarm TypesGas alarmMan-downTrouble
Low and high adjustable

1st – self reset

2nd – latching

Low flow

Sensor connection

Low battery

Circuit error

Calibration range

Sample MethodSample draw pump, flow rate 0.45 LPM, 50 foot sample range
DisplayDigital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases
Audible Alarm95 dB at 1 ft.
LanguagesEnglish, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian
Continuous
Operation

14 hours on Lithium-ion battery pack. Complete recharge in 3 hours.

8 hours Alkaline battery pack (3 AA size within each pack)

Operating Temp.
& Humidity
-4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing
Dimensions2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm)
14 ounce (400g) (with lithium battery pack)
Case MaterialDust and water resistant with IP-67 approval
(exclude sample hose and probe)

Safety Design /

Approvals

Explosion proof: IECEx , ATEX , TIIS , cCSAus

Explosion class :Ex ia IIC T4 Ga Others: CE Marking

Standard
Features

2 Smart sensors slots auto recognize sensor changes

Library of over 600 VOC’s

User defined VOC list. Up to 30 frequently used

Recent VOC list for last 8 selected gases

Pump and circuit status indicators

User & station ID selection menu

Datalogging (interval, alarm trend, station and user ID)

Snap logging – on demand data logging

Demand zero / Auto zero

BUMP and CAL expiration alarm

Flashlight

IrDA communication

LEL sensor protection mode

Standard
Accessories
• Rubber boot • Belt clip
• Hand strap • Tapper nozzle• Probe with hydrophobic & dust filter 3’ teflon lined hose• Benzene pre-filter tubes and holder (benzene versions)
Optional
Accessories

• SDM-6000 calibration station

• Bundles with instrument carrying case and accessories

• Flexible probes

• Up to 50 foot sample hoses

• Filter set

• IrDA cable

WarrantyTwo years material (including sensors) and
workmanship. One year for PID sensor (Two monthsfor 11.7 eV lamp)
  • 6 Operating modes
  • Smallest 6 gas sample draw
  • 2 Interchangeable smart sensor slots
  • 4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
  • PID library of over 600 VOCs
    — Easily switch target VOC from customizable user list or a recently used list
  • Benzene specific version
  • PPM Leak Check mode
  • LEL sensor protection mode
  • Man-down alarm
  • Panic alarm • Auto display rotation
  • Peak-bar display
  • LED Light source
  • Internal sample pump
  • Light weight, small, rugged IP-67 design
  • Interchangeable battery packs (Li-ion / alkaline)
  • Operates up to 14 hours on Li-ion battery pack, fully recharges in 3 hours; 8 hours operation with alkaline pack
  • Field replaceable sensors, batteries, filters and pump
  • Intrinsically safe ATEX / IECEx / cCSAus
  • Confined Space Entry
  • Hazmat Response Teams
  • Arson Investigation
  • Remediation Site
  • Perimeter Monitoring
  • Leak Detection
  • Landfill Monitoring
  • Winery Tank Entry

Gases & Detectable Ranges

GasMeasuring Range

Reading

Increment

Alarm

Set Points

Accuracy

(which ever
is greater)

PID Sensors
10.6 Lamp600 VOC’s0 – 50,000 ppb

1 ppb: (< 5000 ppb)

10 ppb: (> 5,000 ppb)

A1: 5,000 ppb

± 10% of reading,

± 1 digit

A2: 10,000 ppb
0 – 6,000 ppm0.1 ppm: (< 600 ppm)
1 ppm: (> 600 ppm)
A1: 400 ppm
A2: 1,000 ppm
10.0 LampBenzene Specific0.1 – 50 ppm0.01 ppm (0 ~ 10 ppm)
0.1 ppm (10 ~ 50 ppm)
No Alarms
300 VOC’s0 – 100 ppm0.01 ppm (0 ~ 10 ppm)
0.1 ppm (10 ~ 100 ppm)

A1: 5 ppm

A2: 10 ppm

11.7 LampHigh Voltage Lamp0 – 1000 ppm0.1 ppmA1: 400 ppm
A2: 1,000 ppm
Galvanic
Oxygen (O2)0 – 40.0% Vol.0.1% Vol.A1: 19.5 Vol.± 0.5% O2
A2: 23.5 Vol.
Electro Chemical
Carbon Monoxide (CO)0 – 500 ppm1 ppmA1: 25 ppm± 5% of
reading or
± 5 ppm
A2: 50 ppm
TWA 25 ppm
STEL 200 ppm
Hydrogen Sulfide (H2S)0 – 100.0 ppm0.5 ppmA1: 5.0 ppm± 5% of
reading or
± 2 ppm
A2: 30.0 ppm
TWA 1.0 ppm
STEL 5.0 ppm
Toxics (EC Sensors)
Ammonia (NH3)0 – 400.0 ppm0.5 ppmA1: 25 ppm± 10% of
reading or ± 5% of full scale
A2: 50 ppm
Chlorine
(Cl2)
0 – 10.00 ppm0.05 ppmA1: 0.5 ppm
A2: 1.0 ppm
Hydrogen Cyanide (HCN)0 – 15.0 ppm0.1 ppmA1: 5 ppm
A2: 10 ppm
Nitrogen Dioxide (NO2)0 – 20.00 ppm0.05 ppmA1: 3 ppm
A2: 6 ppm
Sulfur Dioxide (SO2)0 – 99.90 ppmA1: 2 ppm
A2: 5 ppm
IR Sensors
Carbon Dioxide (CO2)0 – 10,000 ppm20 ppmA1: 5,000 ppm± 5% of
reading or ± 2% of full scale
TWA 5,000 ppm
0 – 10.00% Vol.0.02%A1: 0.50% Vol
A2: 3.00% Vol
STEL 3.00% Vol
TWA 0.50% Vol
Methane (CH4)

0 – 100% LEL

0 – 100% Vol.

1% LEL/
0.5% Vol

A1: 10% LEL

A2: 50% LEL

Hydrocarbons0 – 100% LEL
0 – 30% Vol.
Catalytic
Hydrocarbons (CH4, std)0 – 100% LEL1% LELA1: 10%LEL± 5% of
reading or ± 2% LEL
A2: 50%LEL

Common Specifications

Alarm TypesGas alarmMan-downTrouble
Low and high adjustable

1st – self reset

2nd – latching

Low flow

Sensor connection

Low battery

Circuit error

Calibration range

Sample MethodSample draw pump, flow rate 0.45 LPM, 50 foot sample range
DisplayDigital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases
Audible Alarm95 dB at 1 ft.
LanguagesEnglish, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian
Continuous
Operation

14 hours on Lithium-ion battery pack. Complete recharge in 3 hours.

8 hours Alkaline battery pack (3 AA size within each pack)

Operating Temp.
& Humidity
-4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing
Dimensions2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm)
14 ounce (400g) (with lithium battery pack)
Case MaterialDust and water resistant with IP-67 approval
(exclude sample hose and probe)

Safety Design /

Approvals

Explosion proof: IECEx , ATEX , TIIS , cCSAus

Explosion class :Ex ia IIC T4 Ga Others: CE Marking

Standard
Features

2 Smart sensors slots auto recognize sensor changes

Library of over 600 VOC’s

User defined VOC list. Up to 30 frequently used

Recent VOC list for last 8 selected gases

Pump and circuit status indicators

User & station ID selection menu

Datalogging (interval, alarm trend, station and user ID)

Snap logging – on demand data logging

Demand zero / Auto zero

BUMP and CAL expiration alarm

Flashlight

IrDA communication

LEL sensor protection mode

Standard
Accessories

• Rubber boot • Belt clip
• Hand strap • Tapper nozzle

• Probe with hydrophobic & dust filter 3’ teflon lined hose

• Benzene pre-filter tubes and holder (benzene versions)

Optional
Accessories

• SDM-6000 calibration station

• Bundles with instrument carrying case and accessories

• Flexible probes

• Up to 50 foot sample hoses

• Filter set

• IrDA cable

Warranty

Two years material (including sensors) and
workmanship. One year for PID sensor (Two months

for 11.7 eV lamp)

GX 6000

download datasheet

Driven By Values, Delivering On A Vision.