RM 5000 - Multi Gas Monitor System
- Description
- Features
- Applications
- Display Indication
- Specifications
- Download
A multi-channel gas monitor system for monitoring combustible gases, oxygen, and toxic gases.
It can be used with existing multi/single cas of RM-570A / RM-580 series by use of connection case 5000-CC without new installation work. Also it is compatible as a replacement to use in existing facility expansion. RM 5000
- Bar meter and digital multi-indication
- High level of visibility
- Low power consumption
- Support RS-485 communication function
- Global standard
- Combatible with RM-570A/580 series
- LPG, LNG utlities
- Refineries
- Chemical plants
- Semi-conductor manufacturing plants
- Engineering, public works
- Power station
- Iron and steel works
- Automotive plating processes
Display Indication
Display indicates gas concentration by two methods; bar meter and digital meter. LCD will change color depending on the concentration level so you can confirm detection condition from a distance. RM-5000 color displays Maximum of 32 points can be connected to use RS-485.Specifications
RM-5000 Series | GP-5001 NC-5001 NC-5001W | NP-5001 | SP-5001 | GH-5001 |
Detection Gas | Combustible | Combustible Inert Gases | Combustible/Toxic | |
Indication | Character LCD (Digital and bar meter) Green, Yellow, Red (3-colors) | |||
Type of acceptable detector head | Catalytic combustion new ceramic | Thermal conductivity | Special catalytic/semiconductor combination sensor | semiconductor |
Acceptable input signal | Direct sensor signal | |||
Applicable cable | CVV-4C | CVVS-4C | CVV-4C | CVVS-3C |
Max distance | Max 2.0km | |||
Output signal | Ouput of electric power transmission (non-isolated) 4-20mADC, max loop load 300Ω | |||
Alamr indication | Flashing or lighting lamp: Red (alarm1), Red (alarm2), Self-latching or Auto reset, Lock-in | |||
Trouble Alarm | Orange lamp flashing (fault), non-latching / content indication | |||
Alarm relays | Normally energized or de-energized normally-open or closed contact rated 0.5A at 100VAC, 1.5A at 30VDC (resistive) | |||
Operating condition | -10~+40C (14 F to 104 F), 10~90% RH (non-condensing) | |||
Power supply | 24VDC | |||
Power consumption | Max 7W | |||
Dimensions & weight | Approx. 1.16w x 4.72h x 3.62d inches | |||
Structure | Card type with front display enclosed in a case (a single-unit or multi-unit case) |
RM-5000 Series | EC-5002 | OX-5001 | OX-5002 | RM-5002 | RM-5003 |
Detection Gas | Toxic | Oxygen | Combustible, Toxic, Oxygen | ||
Indication | Character LCD (Digital and bar meter) Green, Yellow, Red (3-colors) | ||||
Type of acceptable detector head | Electrochemical cell | Galvanic cell | 4-20mA outputs | ||
2-wire type | 3-wire type | ||||
Acceptable input signal | 4-20mA output | Direct Sensor | 4-20mA output | ||
Applicable cable | CVVS-2C | CVVS-3C | |||
Max distance | Max 2.0km | Max 600m | Max 2.0km | Depending on the detector | |
Output signal | Ouput of electric power transmission (non-isolated) 4-20mADC, max loop load 300Ω | ||||
Alamr indication | Flashing or lighting lamp: Red (alarm1), Red (alarm2), Self-latching or Auto reset, Lock-in | ||||
Trouble Alarm | Orange lamp flashing (fault), non-latching / content indication | ||||
Alarm relays | Normally energized or de-energized normally-open or closed contact rated 0.5A at 100VAC, 1.5A at 30VDC (resistive) | ||||
Operating condition | -10~+40C (14 F to 104 F), 10~90% RH (non-condensing) | ||||
Power supply | 24VDC | ||||
Power consumption | Max 3W | Max 2W | Max 3W | Max 2W | Max 8W |
Dimensions & weight | Approx. 1.16w x 4.72h x 3.62d inches | ||||
Structure | Card type with front display enclosed in a case (a single-unit or multi-unit case) |