RX-8000 Marine Gas Monitor
Previous
Next
- Description
- Features
- Applications
- Overview
- Specifications
- Download
The RX-8000 is an ideal multigas monitor for marine applications. RX 8000
- Real-time detection combustible gas, 100%vol./ 100%LEL & O2
- Large simultaneous display with auto back lighting
- Strong sample drawing capability
- Loud alarm buzzer with 95dB
- 3 bright LED alarm indicators
- ATEX Exia II CT4/MED approved
- Water and dust resistant IP67
- Lithium-ion rechargeable battery
- Compact and lightweight
- Internal sample draw pump
- Ergonomic design with wrist strap for hands free operation
- Datalogging standard
Category: Multi-Gas
- Oil Tanker
- Gas Carrier
- Product Tanker
- Refineries, Petrochemical, Chemical Plants
- Confined Space Entry
- Gas Plant, Gas Supplier Services
- Power Plant
- Chemical Tanker
- Wastewater Treatment / Water
- Utilities
The RX-8000 sets the new industry standard for rugged, reliable portable gas detection. It’s tough, water proof design utilized features based on years of gas detection design experience, to assure that the instrument will operate properly to protect workers and property in all kinds of harsh gas detection applications.
Target Gas | Combustibles (i-CH410 or CH4 calibration) | Oxygen | |
Detection Principle | Non-Dispersive Infrared (IR) | Galvanic Cell | |
Detection Range (Increments) | 0-100vol% (0.5vol%) | 0-100%LEL (0.5%LEL) | 0-40.0% (0.1%) |
Accuracy | ±5vol% | ±5vol% | Range 0-25%: ±0.7 |
Response Time | T90 within 30 seconds | T90 within 20 seconds | |
Sampling Method | Sample Draw: Minimum 0.75L/min | ||
Gas Alarm | N/A | 1st: 10%LEL | 1st: 19.5% 2nd: 23.5% |
Display of Alarm | LED: LED’s flash Buzzer: 95dB Visual Indication: Indication value flashes. Alarm message displays and flashes | ||
Display | Digital display and bar graph | ||
Power Source | Lithium-ion battery (3 hours for a full charge): Standard AA Alkaline battery (qty 3): Option | ||
Continuous Operation | Lithium-ion battery: 15 hours AA Alkaline battery: 10 hours | ||
Operating Temp & Humidity | -20 ~ +50C (-4 ~ +122F) below 95%Rh (non-condensing) | ||
Dimensions & Weight | 6.1″W x 3.1″H x 5″ D, 2.4lbs | ||
Ingress Proof Rating | IP67 | ||
Explosion Proof | Ex ia IIC T4 Ga | ||
Approvals | IECEx, ATEX, MED, Complying to IEC60079-29-1, EN50104 | ||
Additional Features | Indication to show energizing (pilot indicator and pump driving indicator), activating confirmation IrDA communication, data logger, password protection |
RX-8000 Software & Documents | |||
Software | Product Datasheet | RX-8000 Manuals | |