S2 Series Diffusion Sensor

  • Available gases include
    LEL, H2S, CO, PPM H2, and CO2
    Toxic gases include NH3, SO2, HCN, and more
  • Infrared sensor for combustibles and CO2
  • Hydrogen-Specific now available
  • Patented water repellent sensor coating
  • 4-20 mA output
  • Explosion proof construction
  • Optional stainless steel junction box
  • Description
  • Features
  • Applications
  • Specifications
  • Download

The RKI S2 series gas sensor/transmitters are highly reliable and very cost effective for the detection of common gas hazards. The S2 series are available for LEL, H2 Specific (LEL, and ppm), Oxygen, H2S, CO, and for a variety of toxic gases. The transmitters for LEL, H2 Specific, Oxygen, H2S, CO2, and Carbon Monoxide are explosion-proof with flame arrestors, and approved for use in hazardous areas (Class l, Groups B, C, D). An optional non-explosion proof version is available for oxygen, H2S, CO, and CO2 in non-hazardous atmospheres. LEL sensors are available using catalytic bead and infrared technologies.

The toxic sensors are electrochemical type plug-in sensors, which provide high specificity, fast response, and long life. The plug-in design allows quick replacement in the field with no tools required. Toxic sensors are designed for use in Class I, Div. 2 hazardous locations. Sensors available for NH3, SO2, PH3, AsH3, and HCN.

The S2 transmitters can be used either indoors or outdoors. The flame arrestors for the explosion-proof versions utilize a patented coating which make them water repellent. Splash guards are also available for use in very wet environments. An optional stainless steel junction box is available for corrosive environments.

All of the S2 transmitters are designed to interface with RKI controllers, or with PLC/DCS systems.

  • Available gases include
    LEL, H2S, CO, PPM H2, and CO2
    Toxic gases include NH3, SO2, HCN, and more
  • Infrared sensor for combustibles and CO2
  • Hydrogen-Specific now available
  • Patented water repellent sensor coating
  • 4-20 mA output
  • Explosion proof construction
  • Optional stainless steel junction box
  • Petrochemical Plants
  • Refineries
  • Gas Plants
  • Offshore Drilling Platforms
  • Water & wastewater treatment plants
  • Pulp & paper mills
  • Gas, telephone, & electric utilities
  • Parking garages
  • Manufacturing facilities
  • Steel
  • Automotive
  • Chemical storage buildings

Explosion Proof Specifications

 

LEL

General Purpose

LEL

H2 Specific

H2 PPM

Hydrogen

O2

Oxygen

H2S

Hydrogen Sulfide

CO

Carbon Monoxide

CH4

Methane

HC

Hydrocarbons

CO2

Carbon Dioxide

Part #

65-2405RK

65-2451RK

65-2442RK-1000

65-2322RK

65-2331RK

65-2336RK

65-2394RK-CH4

65-2394RK-HC

65-2396RK-02

65-2396RK-03

65-2396RK-05

65-2396RK-10

65-2405RK-05

65-2451RK-05

65-2442RK-2000

Sensor

Catalytic

Metal oxide
semiconductor

Galvanic cell

Electrochemical

Infrared

Measuring Range

0-100% LEL

0-100% LEL

(H2 Specific)

0-1000 ppm

0-25% Vol.

0-100 ppm

0-300 ppm

0-100% LEL

0 - 5000 ppm

0 - 5% Vol.

0 - 50% Vol.

0 - 100% Vol.

0-2000 ppm

Lower Detectable Limit (LDL)

2% of full scale

0.1% Vol.

2% of full scale

Accuracy
(whichever is greater)

± 5% of
reading or
± 2% LEL

± 10% of
reading or
± 5% of full scale

± 0.5% O2

± 5% of
reading
± 2 ppm H2S

± 5% of
reading
± 5 ppm CO

± 5% of
reading or
± 2% of full scale

Response Time (T-90)

30 Seconds

20 Seconds

45 Seconds

90 Seconds

60 Seconds

90 Seconds

30 Seconds

Max Current Draw (24VDC)

70 mA (power wires) 25 mA (signal wires) 3 wires

25 mA max, 2 wires

60 mA (power wires)

25 mA (signal wires) 3 wires

Life
Expectancy

2 to 3 years with normal exposure to flammable gas

3-5 years with normal service

5 years plus with normal service

2-3 years with normal service

5 years plus with normal service

Operating Environment

Location

Indoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D.

Temperature

-40°F to 167°F

-40°C to 75°C

-40°F to 167°F

-40°C to 75°C

-4°F to 113°F

-20°C to 45°C

-40°F to 104°F

-40°C to 40°C

23°F to 104°F

-5°C to 40°C

-40°F to 122°F

-40°C to 50°C

Humidity

0 – 99% RH, non condensing

Housing

Housing J Box

Cast aluminum explosion proof, optional stainless steel J-box available

Sensor

Stainless steel explosion proof

Controls

Zero

Sets transmitter output to 4 mA with zero output from sensor

Span

Sets transmitter output to proper level when span gas is applied

Output

4 – 20 mA signal

Operating Voltage

11 VDC to 30 VDC

19 VDC to 30 VDC

19-30VDC (250 OHMS

impedance max)

11 VDC to 30 VDC

Approvals

65-2405RK

UL

65-2451RK

UL

UL

CSA NRTL

C UL US

65-2405RK-05
CSA

65-2451RK-05
CSA

Controllers

Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410A, and 800, also PLC and DCS systems

Warranty

One year materials and workmanship

 

Non Explosion Proof

 

O2

Oxygen

H2S

Hydrogen Sulfide

CO

Carbon Monoxide

Toxics

See chart below

CO2

Carbon Dioxide

Part #

65-2320RK

65-2330RK

65-2335RK

See chart
below

65-2397RK-02

65-2397RK-03

65-2397RK-05

65-2397RK-10

Sensor

Galvanic cell

Electrochemical

Infrared

Measuring Range

0-25% Vol.

0-100 ppm

0-300 ppm

See chart
below

0 - 5000 ppm

0 - 5% Vol.

0 - 50% Vol.

0 - 100% Vol.

Lower Detectable Limit (LDL)

0.1% Vol.

2% of full scale

Accuracy

(whichever is greater)

± 0.5% O2

± 5% of
reading
± 2 ppm H2S

± 5% of
reading
± 5 ppm CO

± 10% of
reading or
± 5% of full scale

± 5% of
reading or
± 2% of full scale

Response Time (T-90)

20 Seconds

45 Seconds

30 Seconds

60 Seconds

30 Seconds

Max Current Draw (24VDC)

25 mA max, 2 wires

60 mA (power wires)

25 mA (signal wires) 3 wires

Life Expectancy

2 years normal
service

2 to 3 years with normal service

5 years plus with
normal service

Operating Environment

Location

Indoor Class I, Div. 2

Temperature

-4°F to 122°F

-20°C to 50°C

14°F to 104°F

-10°C to 40°C

-40°F to 122°F

-40°C to 50°C

Humidity

0 – 99% RH non condensing

5-95% RH

0 – 99% RH
non condensing

Housing

Housing J-Box

Cast aluminum, explosion-proof

Sensor

Plastic or aluminum

Controls

Zero

Sets transmitter output to 4 mA with zero output from sensor

Span

Sets transmitter output to 20 mA with full scale output from sensor

Operating Voltage

19 VDC to 30 VDC

Output

4-20 mA signal

Controllers

Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410A, and 800, also PLC and DCS systems

Warranty

One year materials and workmanship

S2 toxic sensor

S2 toxic sensor

Non Explosion Proof Toxic Assemblies

Part Number With J-Box

Gas

Range

Resolution

Sensor Type

65-2340RK-NH3

Ammonia (NH3)

0 - 75.0 ppm

0.1 ppm

ESM -01

65-2340RK-AsH3

Arsine (AsH3)

0 - 1.50 ppm

0.01 ppm

ESM -01

65-2341-CL2

Chlorine (Cl2)

0 - 3.00 ppm

0.01 ppm

CT-7

65-2341-CL2-10

Chlorine (Cl2)

0 - 10.0 ppm

0.1 ppm

CT-7

65-2341-CLO2

Chlorine Dioxide (ClO2)

0 - 1.00 ppm

0.01 ppm

CT-7

65-2340RK-HCN

Hydrogen Cyanide (HCN)

0 - 15.0 ppm

0.1 ppm

ESM -01

65-2340RK-PH3

Phosphine (PH3)

0 - 1.00 ppm

0.01 ppm

ESM -01

65-2340RK-SO2

Sulfur Dioxide (SO2)

0 - 6.00 ppm

0.01 ppm

ESM -01

* Partial pressure sensor for helium (He) applications. Consult factory for details.

Direct Interface with Beacon 110 / 200 / 410 / 800 Controllers

S2 Wiring Matrix

S2 Transmitter
Number of Wires to Controller
Maximum Distance to Controller
Beacon 410 Configuration============
18 AWG wire
16 AWG wire
14 AWG wire
LEL / IR / CO2
3
2500 ft.
5,000 ft.
8,000 ft.
Oxygen
2
2500 ft.
5,000 ft.
8,000 ft.
H2S
2
2500 ft.
5,000 ft.
8,000 ft.
CO
2
2500 ft.
5,000 ft.
8,000 ft.
Toxics
2
2500 ft.
5,000 ft.
8,000 ft.

Specifications subject to change without notice.
Made in the USA

Download Datasheet

Driven By Values, Delivering On A Vision.