SDM E2
- Stand-alone station (no connection to PC Required)
- Charging (NiMH batteries)
- Calibration
- Bump Test
- Save bump test and calibration records
- Bump test and calibration records copy to USB jump drive
- 2 Calibration gas ports
- Includes PC software for viewing/archiving bump test and calibration records
- Description
- Applications
- Specifications
- Ordering Info
- Download
The SDM-E2 is a versatile maintenance tool for the Eagle 2 portable gas monitor. This docking station can be used as a stand-alone device for charging, calibration and bump testing, with all records automatically stored for future upload to a PC via USB flash drive (PC software and flash drive included).
Multi Module System
The SDM-E2 can also be connected to a PC for automated calibration bump testing and archiving of datalog data from Eagle 2 instruments. Up to ten SDM-E2 docking stations can be connected simultaneously using USB cables. The SDM-E2 is also equipped with two gas ports to connect up to two calibration gas mixtures to the multi module system.
- Multiple modules connected to a PC (10 max)
- Charging
- Calibration
- Bump Test
- Configure Eagle 2 parameters
- 2 Calibration gas ports
- Archive Bump Test and Calibration records
- Archive data to network location
- Software controlled data retrieval
- Automatic calibration/bump test option
- Windows 7 compatible
Input Power | AC Adapter with 100 – 240 VAC, 50/60 Hz, 0.6A input and 112 VDC, 1.2A output provided as standard. |
Environmental Conditions | • For Indoor Use Only • -10° C to 40° C, below 80% relative humidity, non condensing |
Applicable Instrument | Eagle 2 |
Maximum Number of Records Saved | 200 |
Calibration Gas Ports | Connect up to 2 calibration gas cylinders to each station |
Standard Accessories | • AC adapter • USB flash drive • Single module data viewer software • SDM Docking station PC • Inlet air filter • Instrument manual • 10’ exhaust tube |
81-SDME2-01 | Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing & installation CD |
81-SDME2-02 | Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing, installation CD, & demand flow regulator |
81-SDME2-03 | Calibration station for Eagle 2, model SDM-E2 with AC adaptor, fla sh drive, USB cable, tubing, installationtion CD, demand flow regulator, & 58AL cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2 |
81-SDME2-08-P1 | Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator, 58AL cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2, & 103L cyl 10 ppm isobutylene in Air |
81-SDME2-08-P2 | Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator, 58AL cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2, & 103L cyl 100 ppm isobutylene in Air |
Download datasheet