SDM-E2

SDM E2

  • Stand-alone station (no connection to PC Required)
  • Charging (NiMH batteries)
  • Calibration
  • Bump Test
  • Save bump test and calibration records
  • Bump test and calibration records copy to USB jump drive
  • 2 Calibration gas ports
  • Includes PC software for viewing/archiving bump test and calibration records

The SDM-E2 is a versatile maintenance tool for the Eagle 2 portable gas monitor. This docking station can be used as a stand-alone device for charging, calibration and bump testing, with all records automatically stored for future upload to a PC via USB flash drive (PC software and flash drive included).

Multi Module System
The SDM-E2 can also be connected to a PC for automated calibration bump testing and archiving of datalog data from Eagle 2 instruments. Up to ten SDM-E2 docking stations can be connected simultaneously using USB cables. The SDM-E2 is also equipped with two gas ports to connect up to two calibration gas mixtures to the multi module system.

  • Multiple modules connected to a PC (10 max)
  • Charging
  • Calibration
  • Bump Test
  • Configure Eagle 2 parameters
  • 2 Calibration gas ports
  • Archive Bump Test and Calibration records
  • Archive data to network location
  • Software controlled data retrieval
  • Automatic calibration/bump test option
  • Windows 7 compatible

Input Power

AC Adapter with 100 – 240 VAC, 50/60 Hz, 0.6A input and 112 VDC, 1.2A output provided as standard.

Environmental Conditions

• For Indoor Use Only

• -10° C to 40° C, below 80% relative humidity, non condensing

Applicable Instrument

Eagle 2

Maximum Number of Records Saved

200

Calibration Gas Ports

Connect up to 2 calibration gas cylinders to each station

Standard Accessories

• AC adapter

• USB flash drive

• Single module data viewer software

• SDM Docking station PC
controller software

• Inlet air filter

• Instrument manual

• 10’ exhaust tube

81-SDME2-01

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing & installation CD

81-SDME2-02

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing, installation CD, & demand flow regulator

81-SDME2-03

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, fla sh drive, USB cable, tubing, installationtion CD, demand flow regulator, & 58AL cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2

81-SDME2-08-P1

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator, 58AL cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2, & 103L cyl 10 ppm isobutylene in Air

81-SDME2-08-P2

Calibration station for Eagle 2, model SDM-E2 with AC adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator, 58AL cyl 25 ppm H2S/50 ppm CO/50% LEL CH4/12% O2 in N2, & 103L cyl 100 ppm isobutylene in Air