SDM-2009 : Calibration Station for the GX-3R (Pro)
- Stand-alone station (no PC Required)
- Charging
- Calibration
- Bump Test
- Save Bump Test and Calibration records
- Bump test and calibration records copy to USB jump drive
- Includes PC software for viewing/ archiving bump test and calibration records
- Description
- Applications
- Specifications
- Ordering Info
- Download
RKI’s new SDM-2009 calibration station for the GX-2009 is now available with advanced features for charging, calibration, & bump testing. Once you power up the GX-2009 inside the SDM-2009 calibration module, the GX-2009’s display will indicate whether it’s transmitting data, bump testing, calibrating, as well as the results of the bump test or calibration.
Multi Module System
The SDM-2009 can also be connected to a PC for automated calibration, bump testing, and archiving of logged data including calibration and bump test records, interval and alarm trends. Network up to 10 SDM-2009 stations to charge, calibrate, and bump test 10 instruments simultaneously.
User Guide Poster
Each SDM-2009 ships with a pictorial wall chart user guide. This guide gives the already easy to use cal station a simple pictorial easy step by step guide to calibrating or bump testing a GX-2009. It’s ideal to hang in an instrument shop or wherever the SDM-2009 is located.
- Multiple modules connected to a PC (10 max)
- Charging
- Calibration
- Bump Test
- Automatic calibration/bump test option
- Configure GX-2009 parameters
- Archive Bump Test and Calibration records
- Archive data to network location
- Software controlled data retrieval
- Windows 7 compatible
Input Power | 12 VDC NOTE: AC Adapter with 100 – 240 VAC, 50/60 Hz, 0.6A input and 12 VDC, 1.2A output provided as standard. |
Environmental Conditions | • For Indoor Use Only • -10° C to 40° C, below 80% Relative Humidity, Non-Condensing |
Applicable Instruments | GX-2009 |
Maximum Number of Records Saved | 200 (stand-alone). Unlimited with software |
Number of Calibration Gas Cylinders | 1 Calibration gas, 1 fresh air and 1 exhaust |
Standard Accessories |
|
Docking Station | |
81-SDM2009-01 | Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing & installation CD |
81-SDM2009-02 | Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing, installation CD, & demand flow regulator |
81-SDM2009-03 | Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 58AL cyl H2S (25 ppm)/CO/CH4/O2 |
81-SDM2009-06 | Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 34AL cyl H2S (25 ppm)/CO/CH4/O2 |
Calibration Equipment and Accessories | |
81-0090RK-01 | Cylinder, CO 50 ppm / Methane 50% LEL / O2 12 % in N2, 34L |
81-0090RK-03 | Cylinder, CO 50 ppm / Methane 50% LEL / O2 12 % in N2, 103L |
81-0154RK-02 | Cylinder, H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 58AL |
81-0154RK-04 | Cylinder, H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 34AL |
81-0158RK-02 | Cylinder, H2S 25 ppm / CO 50 ppm / isobutane 50% LEL / O2 12% in N2, 34AL |
81-0158RK-04 | Cylinder, H2S 25 ppm / CO 50 ppm / isobutane 50% LEL / O2 12% in N2, 58AL |
81-1054RK | Regulator, demand flow for 34AL/58AL/103L |
81-1055RK | Regulator, demand flow for 17L/34L steel cylinders |
82-6050RK | USB Hub, 4 port 2.0 for SDM-2012 |
82-6051RK | USB Hub, 7 port 2.0 for SDM-2012 |
71-8007RK | SDM-GX Product CD |
Download datasheet