The SDM-03 is a versatile maintenance tool that automates the testing service of a 03 Series portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via USB flash drive (PC software and flash drive included).
Multi Module System
utomate how you manage and service 03 Series instruments by connecting the SDM-03 to a computer with a USB cable. With the SDM Docking Station controller software, you can simultaneously calibrate, bump test, or archive data for up to ten instruments. Also, download the data logging history from each instrument into one easy to manage locator. SDM-03 stations can be manifolded together to reduce the number of demand flow regulator gas cylinders required.
User Guide Poster
Each SDM-03 ships with a pictorial wall chart user guide. This guide gives the already easy to use cal station a simple pictorial easy step by step guide to calibrating or bump testing a 03 Series. It’s ideal to hang in an instrument shop or wherever the SDM-03 is located.
Stand Alone Station
- Stand-alone station
(no PC Required) - Calibration
- Bump Test
- Save Bump Test and Calibration records
- Bump test and calibration records copy to USB jump drive
- Includes PC software for viewing/ archiving bump test and calibration records
Multi Module System
- Multiple modules connected to a PC (10 max)
- Calibration
- Bump Test
- Automatic calibration/bump test option
- Configure 03 Series parameters
- Archive Bump Test and Calibration records
- Archive data to network location
- Software controlled data retrieval
- Windows 7 compatible
- Stand-alone station
Multi Module System
- Multiple modules connected to a PC (10 max)
- Calibration
- Bump Test
- Automatic calibration/bump test option
- Configure 03 Series parameters
- Archive Bump Test and Calibration records
- Archive data to network location
- Software controlled data retrieval
- Windows 7 compatible
Input Power |
|
Environmental Conditions |
|
Applicable Instruments |
|
Maximum Number of Records Saved |
|
3 Ports |
|
Standard Accessories |
|
Specifications subject to change without notice.
Gases & Detectable Ranges | |||||
Gas | Measuring Range | Reading Increment | Alarm Set Points | Accuracy (which ever | |
PID Sensors | |||||
10.6 Lamp | 600 VOC’s | 0 – 50,000 ppb | 1 ppb: (< 5000 ppb) 10 ppb: (> 5,000 ppb) | A1: 5,000 ppb | ± 10% of reading, ± 1 digit |
A2: 10,000 ppb | |||||
0 – 6,000 ppm | 0.1 ppm: (< 600 ppm) 1 ppm: (> 600 ppm) | A1: 400 ppm | |||
A2: 1,000 ppm | |||||
10.0 Lamp | Benzene Specific | 0.1 – 50 ppm | 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm) | No Alarms | |
300 VOC’s | 0 – 100 ppm | 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm) | A1: 5 ppm A2: 10 ppm | ||
11.7 Lamp | High Voltage Lamp | 0 – 1000 ppm | 0.1 ppm | A1: 400 ppm | |
A2: 1,000 ppm | |||||
Galvanic | |||||
Oxygen (O2) | 0 – 40.0% Vol. | 0.1% Vol. | A1: 19.5 Vol. | ± 0.5% O2 | |
A2: 23.5 Vol. | |||||
Electro Chemical | |||||
Carbon Monoxide (CO) | 0 – 500 ppm | 1 ppm | A1: 25 ppm | ± 5% of reading or ± 5 ppm | |
A2: 50 ppm | |||||
TWA 25 ppm | |||||
STEL 200 ppm | |||||
Hydrogen Sulfide (H2S) | 0 – 100.0 ppm | 0.5 ppm | A1: 5.0 ppm | ± 5% of reading or ± 2 ppm | |
A2: 30.0 ppm | |||||
TWA 1.0 ppm | |||||
STEL 5.0 ppm | |||||
Toxics (EC Sensors) | |||||
Ammonia (NH3) | 0 – 400.0 ppm | 0.5 ppm | A1: 25 ppm | ± 10% of reading or ± 5% of full scale | |
A2: 50 ppm | |||||
Chlorine (Cl2) | 0 – 10.00 ppm | 0.05 ppm | A1: 0.5 ppm | ||
A2: 1.0 ppm | |||||
Hydrogen Cyanide (HCN) | 0 – 15.0 ppm | 0.1 ppm | A1: 5 ppm | ||
A2: 10 ppm | |||||
Nitrogen Dioxide (NO2) | 0 – 20.00 ppm | 0.05 ppm | A1: 3 ppm | ||
A2: 6 ppm | |||||
Sulfur Dioxide (SO2) | 0 – 99.90 ppm | A1: 2 ppm | |||
A2: 5 ppm | |||||
IR Sensors | |||||
Carbon Dioxide (CO2) | 0 – 10,000 ppm | 20 ppm | A1: 5,000 ppm | ± 5% of reading or ± 2% of full scale | |
TWA 5,000 ppm | |||||
0 – 10.00% Vol. | 0.02% | A1: 0.50% Vol | |||
A2: 3.00% Vol | |||||
STEL 3.00% Vol | |||||
TWA 0.50% Vol | |||||
Methane (CH4) | 0 – 100% LEL 0 – 100% Vol. | 1% LEL/ 0.5% Vol | A1: 10% LEL A2: 50% LEL | ||
Hydrocarbons | 0 – 100% LEL 0 – 30% Vol. | ||||
Catalytic | |||||
Hydrocarbons (CH4, std) | 0 – 100% LEL | 1% LEL | A1: 10%LEL | ± 5% of reading or ± 2% LEL | |
A2: 50%LEL |
Common Specifications | |||
Alarm Types | Gas alarm | Man-down | Trouble |
Low and high adjustable | 1st – self reset 2nd – latching | Low flow Sensor connection Low battery Circuit error Calibration range | |
Sample Method | Sample draw pump, flow rate 0.45 LPM, 50 foot sample range | ||
Display | Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases | ||
Audible Alarm | 95 dB at 1 ft. | ||
Languages | English, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian | ||
Continuous Operation | 14 hours on Lithium-ion battery pack. Complete recharge in 3 hours. 8 hours Alkaline battery pack (3 AA size within each pack) | ||
Operating Temp. & Humidity | -4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing | ||
Dimensions | 2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm) 14 ounce (400g) (with lithium battery pack) | ||
Case Material | Dust and water resistant with IP-67 approval (exclude sample hose and probe) | ||
Safety Design / Approvals | Explosion proof: IECEx , ATEX , TIIS , cCSAus Explosion class :Ex ia IIC T4 Ga Others: CE Marking | ||
Standard | 2 Smart sensors slots auto recognize sensor changes Library of over 600 VOC’s User defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases Pump and circuit status indicators User & station ID selection menu Datalogging (interval, alarm trend, station and user ID) Snap logging – on demand data logging Demand zero / Auto zero BUMP and CAL expiration alarm Flashlight IrDA communication LEL sensor protection mode | ||
Standard Accessories | • Rubber boot • Belt clip • Probe with hydrophobic & dust filter 3’ teflon lined hose • Benzene pre-filter tubes and holder (benzene versions) | ||
Optional Accessories | • SDM-6000 calibration station • Bundles with instrument carrying case and accessories • Flexible probes • Up to 50 foot sample hoses • Filter set • IrDA cable | ||
Warranty | Two years material (including sensors) and for 11.7 eV lamp) |
Docking Station | |
81-SDM03-01 | Single point calibration station for O3 Series, model SDM-03 with AC Adaptor, flash drive, USB cable, tubing & installation CD |
81-SDM03-02 | Single point calibration station for O3 Series, model SDM-03 with AC Adaptor, flash drive, USB cable, tubing, installation CD, & demand flow regulator |
81-SDM03-03-GP | Single point calibration station for O3 Series, model SDM-03 with AC Adaptor, flash drive, USB cable, tubing, installation CD |
81-SDM03-06-GP | Single point calibration station for O3 Series, model SDM-03 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 34AL cyl 50% LEL CH4/Air |
81-SDM03-03-CO | Single point calibration station for O3 Series, model SDM-03 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 103L cyl 50 ppm CO/N2 |
81-SDM03-06-CO | Single point calibration station for O3 Series, model SDM-03 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 34AL cyl 50 ppm CO/N2 |
81-SDM03-03-HS | Single point calibration station for O3 Series, model SDM-03 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 58AL cyl 25 ppm H2S/N2 |
81-SDM03-06-HS | Single point calibration station for O3 Series, model SDM-03 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 34AL cyl 25 ppm H2S/N2 |
Calibration Equipment and Accessories | |
81-0090RK-01 | Cylinder, CO 50 ppm / Methane 50% LEL / O2 12 % in N2, 34L |
81-0090RK-03 | Cylinder, CO 50 ppm / Methane 50% LEL / O2 12 % in N2, 103L |
81-0154RK-02 | Cylinder, H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 58AL |
81-0154RK-04 | Cylinder, H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 34AL |
81-0158RK-02 | Cylinder, H2S 25 ppm / CO 50 ppm / isobutane 50% LEL / O2 12% in N2, 34AL |
81-0158RK-04 | Cylinder, H2S 25 ppm / CO 50 ppm / isobutane 50% LEL / O2 12% in N2, 58AL |
81-1054RK | Regulator, demand flow for 34AL/58AL/103L |
81-1055RK | Regulator, demand flow for 17L/34L steel cylinders |
82-6050RK | USB Hub, 4 port 2.0 for SDM-2012 |
82-6051RK | USB Hub, 7 port 2.0 for SDM-2012 |
71-8007RK | SDM-GX Product CD |
Specifications subject to change without notice
SDM-03 Software | ||
![]() SDM-03 PC Controlled Software 30MB | ![]() SDM-03 Standalone Configuration Software 53MB | |
![]() PC Controlled Configuration manual 6MB | ![]() Standalone Configuration Manual 900KB | |
SDM-03 Literature | ||
![]() SDM-03 Datatsheet | ![]() SDM-03 User Guide | |
SDM-03 Manuals | ||
![]() SDM-03 Standalone Configuration Operator’s Manual | ![]() SDM-03 PC Controlled Configuration Operator’s Manual |