Features
- Monitors ppm LEL, % volume methane, O2, CO and H2S
- 0 to 100% volume methane option
- Auto-ranging display of % LEL and % volume
- 3 Operating modes: Normal, leak check, & bar hole
- PPM leak detector
- Adjustable display ranges
- Visual / audible pulses change with gas concentration
- CO display in leak check mode
- Barhole test mode for underground leak checks
- Internal sample drawing pump with up to 50′
- Vibration, visual, and audible alarms
- Automatic backlight during alarms
- Lithium ion or alkaline battery packs (interchangeable)
- Intrinsically safe, ATEX/IECEx/CE or CSA/CE (Optional)
- Description
- Applications
- Specifications
- Parts
- Download
- Training Video
With the GX-2012, you have multiple tools in one instrument. Having 3 operating modes, the GX-2012 can be used for confined space, safety monitoring in it’s Normal Operating mode; for leak investigation in Leak Check mode; and for underground leak checking in Bar Hole mode. When equipped with an optional TC sensor, the GX-2012 can measure 100% volume methane and dynamically auto range from % LEL to % volume. This is ideal for line purge testing.
Built around high-quality micro-sensor technology, the GX-2012 is RKI’s smallest personal 1-5 sensor gas monitor with a built in sample pump. Weighing only 12.3 ounces, the GX-2012 can monitor the standard confined space gases (LEL combustibles, Oxygen content, Carbon Monoxide, and Hydrogen Sulfide).
The GX-2012’s large LCD display shows all gas readings, battery level, current time, and will automatically backlight in alarm conditions. Standard alarm types include vibration, visual, and audible alarms, which can be set to latching or non-latching. Controlled by a microprocessor, the GX-2012 continuously checks itself for sensor connections, low battery, circuit trouble, low flow, and calibration errors. The GX-2012 can interchangeably operate on either a Li-ion battery pack or an alkaline battery pack. The batteries are simple to replace requiring no tools to access the removable battery compartment or pack.
Gas Detected | Combustible Gases | % Volume | Oxygen (O2) | Hydrogen Sulfide (H2S) | Carbon Monoxide (CO) |
Detection Principle | Catalytic combustion | Thermal conductivity | Galvanic cell | Electrochemical cell | |
Detection Range | 0 ~ 100% LEL | 0 ~ 100% Vol. | 0 ~ 40% Vol. | 0 ~ 100 ppm | 0 ~ 500 ppm |
Accuracy Statement | ± 5% of reading or (LEL mode only) | ± 5% of reading or ± 2% of full scale | ± 0.5% O2 | ± 5% of reading or ± 2ppm H2S | ± 5% of reading or ± 5 ppm CO |
Sampling Method | Internal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter | ||||
Display | Digital LCD with 7 segments, auto backlight during alarm | ||||
Preset Alarms | 1st alarm 10% LEL | No alarms for | Low alarm 19.5% High alarm 23.5% Over alarm 40.0% | 1st 5 ppm | 1st 25 ppm |
Alarms Types | Gas alarms: 1st and 2nd, STEL, TWA (user adjustable) and OVER | ||||
Alarm Methods | Gas alarms: Flashing lights, two tone buzzer, and vibration | ||||
Operating Temp. & Humidity | -20°C to +50°C (-4°F to 122°F) | ||||
Response Time | Within 30 seconds (T90) | ||||
Continuous Operation | Alkaline battery: 15 hours Li-Ion battery: 10 hours | ||||
Power Source | Li-Ion battery pack, or 3 “AA” Alkaline battery pack; interchangeable | ||||
Safety Rating | ATEX, TIIS, IECEx, CE, CSA classified (as standard), as intrinsically safe. Class I, Division 1, Groups A, B, C, D (optional version available) | ||||
Dimension & Weight | Approx. 143 (H) x 71 (W) x 43 (D) mm (5.6” H x 2.8” W x 1.6” D), approx. 350 g (12.3 ounces) | ||||
Case Material | High dust & water resistant design. RFI shielded high impact plastic with protective rubber overmolding | ||||
Controls | Five buttons: POWER / ENTER, DISPLAY, AIR, RESET, SHIFT | ||||
Standard Accessories |
| ||||
Optional Accessories |
| ||||
Configurations | 1, 2, 3, 4, or 5 sensor units | ||||
Warranty | Two years material and workmanship |
- Confined Space Entry
- Hazmat Response Teams
- Arson Investigation
- Remediation Site
- Perimeter Monitoring
- Leak Detection
- Landfill Monitoring
- Winery Tank Entry
Gases & Detectable Ranges | |||||
Gas | Measuring Range | Reading Increment | Alarm Set Points | Accuracy (which ever | |
PID Sensors | |||||
10.6 Lamp | 600 VOC’s | 0 – 50,000 ppb | 1 ppb: (< 5000 ppb) 10 ppb: (> 5,000 ppb) | A1: 5,000 ppb | ± 10% of reading, ± 1 digit |
A2: 10,000 ppb | |||||
0 – 6,000 ppm | 0.1 ppm: (< 600 ppm) 1 ppm: (> 600 ppm) | A1: 400 ppm | |||
A2: 1,000 ppm | |||||
10.0 Lamp | Benzene Specific | 0.1 – 50 ppm | 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm) | No Alarms | |
300 VOC’s | 0 – 100 ppm | 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm) | A1: 5 ppm A2: 10 ppm | ||
11.7 Lamp | High Voltage Lamp | 0 – 1000 ppm | 0.1 ppm | A1: 400 ppm | |
A2: 1,000 ppm | |||||
Galvanic | |||||
Oxygen (O2) | 0 – 40.0% Vol. | 0.1% Vol. | A1: 19.5 Vol. | ± 0.5% O2 | |
A2: 23.5 Vol. | |||||
Electro Chemical | |||||
Carbon Monoxide (CO) | 0 – 500 ppm | 1 ppm | A1: 25 ppm | ± 5% of reading or ± 5 ppm | |
A2: 50 ppm | |||||
TWA 25 ppm | |||||
STEL 200 ppm | |||||
Hydrogen Sulfide (H2S) | 0 – 100.0 ppm | 0.5 ppm | A1: 5.0 ppm | ± 5% of reading or ± 2 ppm | |
A2: 30.0 ppm | |||||
TWA 1.0 ppm | |||||
STEL 5.0 ppm | |||||
Toxics (EC Sensors) | |||||
Ammonia (NH3) | 0 – 400.0 ppm | 0.5 ppm | A1: 25 ppm | ± 10% of reading or ± 5% of full scale | |
A2: 50 ppm | |||||
Chlorine (Cl2) | 0 – 10.00 ppm | 0.05 ppm | A1: 0.5 ppm | ||
A2: 1.0 ppm | |||||
Hydrogen Cyanide (HCN) | 0 – 15.0 ppm | 0.1 ppm | A1: 5 ppm | ||
A2: 10 ppm | |||||
Nitrogen Dioxide (NO2) | 0 – 20.00 ppm | 0.05 ppm | A1: 3 ppm | ||
A2: 6 ppm | |||||
Sulfur Dioxide (SO2) | 0 – 99.90 ppm | A1: 2 ppm | |||
A2: 5 ppm | |||||
IR Sensors | |||||
Carbon Dioxide (CO2) | 0 – 10,000 ppm | 20 ppm | A1: 5,000 ppm | ± 5% of reading or ± 2% of full scale | |
TWA 5,000 ppm | |||||
0 – 10.00% Vol. | 0.02% | A1: 0.50% Vol | |||
A2: 3.00% Vol | |||||
STEL 3.00% Vol | |||||
TWA 0.50% Vol | |||||
Methane (CH4) | 0 – 100% LEL 0 – 100% Vol. | 1% LEL/ 0.5% Vol | A1: 10% LEL A2: 50% LEL | ||
Hydrocarbons | 0 – 100% LEL 0 – 30% Vol. | ||||
Catalytic | |||||
Hydrocarbons (CH4, std) | 0 – 100% LEL | 1% LEL | A1: 10%LEL | ± 5% of reading or ± 2% LEL | |
A2: 50%LEL |
Common Specifications | |||
Alarm Types | Gas alarm | Man-down | Trouble |
Low and high adjustable | 1st – self reset 2nd – latching | Low flow Sensor connection Low battery Circuit error Calibration range
| |
Sample Method | Sample draw pump, flow rate 0.45 LPM, 50 foot sample range | ||
Display | Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases | ||
Audible Alarm | 95 dB at 1 ft. | ||
Languages | English, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian | ||
Continuous Operation | 14 hours on Lithium-ion battery pack. Complete recharge in 3 hours. 8 hours Alkaline battery pack (3 AA size within each pack) | ||
Operating Temp. & Humidity | -4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing | ||
Dimensions | 2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm) 14 ounce (400g) (with lithium battery pack) | ||
Case Material | Dust and water resistant with IP-67 approval (exclude sample hose and probe) | ||
Safety Design / Approvals | Explosion proof: IECEx , ATEX , TIIS , cCSAus Explosion class :Ex ia IIC T4 Ga Others: CE Marking | ||
Standard | 2 Smart sensors slots auto recognize sensor changes Library of over 600 VOC’s User defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases Pump and circuit status indicators User & station ID selection menu Datalogging (interval, alarm trend, station and user ID) Snap logging – on demand data logging Demand zero / Auto zero BUMP and CAL expiration alarm Flashlight IrDA communication LEL sensor protection mode | ||
Standard Accessories | • Rubber boot • Belt clip • Hand strap • Tapper nozzle • Probe with hydrophobic & dust filter 3’ teflon lined hose • Benzene pre-filter tubes and holder (benzene versions) | ||
Optional Accessories | • SDM-6000 calibration station • Bundles with instrument carrying case and accessories • Flexible probes • Up to 50 foot sample hoses • Filter set • IrDA cable
| ||
Warranty | Two years material (including sensors) and workmanship. One year for PID sensor (Two months for 11.7 eV lamp) |
GX-6000 Software | ||||
GX-6000 Firmware Update Instructions(step by step procedure) | TWA Alarm Setting for continuous operation(step by step procedure for turning off TWA Alarms) | |||
Manuals & Literature | ||||
GX-6000 Product Datatsheet | GX-6000 PID Datatsheet | GX-6000 Brochure | ||